CDM3-250F/42002B 140A塑壳断路器产品介绍
一、产品概述
CDM3-250F/42002B 140A塑壳断路器是为低压配电系统开发的保护装置,采用模块化设计理念,适用于额定工作电压至690V,额定电流140A的交流电路中。产品具备过载、短路保护功能,通过优化电弧能量控制技术,有效提升设备运行稳定性。紧凑型结构设计在保证性能的同时,节省了配电柜空间占用。
二、结构特点
- 创新灭弧系统:采用多级气吹灭弧结构,通过优化灭弧栅片布局,缩短电弧停滞时间,提升分断可靠性
- 精密脱扣机构:双金属片与电磁系统协同工作,实现精确的电流-时间特性配合,动作误差控制在±10%以内
- 模块化附件:支持加装辅助触点、分励脱扣等扩展模块,满足多样化控制需求
- 强化壳体结构:工程塑料外壳经耐候性改良,具备抗冲击、耐腐蚀特性,防护等级达到IP40
三、应用场景
本产品主要应用于:
- 工业厂房配电系统主干线路保护
- 商业建筑楼层配电箱总开关
- 光伏发电系统直流侧过流防护
- 港口机械动力回路控制节点
- 轨道交通辅助供电单元
四、安全保护机制
配备可视化分合闸指示窗,通过机械联锁装置防止误操作。触头系统采用银基合金材料,配合V型开槽设计,确保长期使用后仍能保持良好接触特性。内部隔离板采用阻燃材料,有效防止故障电弧扩散。
五、操作与维护
旋转手柄操作力矩≤6N·m,符合人体工程学设计。提供三档脱扣力调节功能(70%/100%/140%),可根据实际负载特性灵活设置。维护周期建议每12个月进行触点清洁检查,环境恶劣场所可缩短至6个月。
CDM3-250F/42002B 140A Molded Case Circuit Breaker Introduction
I. Product Overview
The CDM3-250F/42002B 140A molded case circuit breaker is designed for low-voltage distribution systems, featuring modular construction suitable for AC circuits up to 690V with 140A rated current. Integrating overload and short-circuit protection functions, it employs optimized arc energy control technology to enhance operational stability. The compact design ensures reliable performance while minimizing panel space requirements.
II. Structural Features
- Advanced Arc-Extinguishing System: Multi-stage gas blast arc chamber with optimized splitter plate arrangement reduces arc duration and improves breaking reliability
- Precision Trip Mechanism: Bimetal-electromagnetic hybrid system achieves accurate current-time coordination with ±10% operating tolerance
- Modular Accessories: Compatible with auxiliary contacts and shunt releases for expanded control functions
- Reinforced Enclosure: Weather-resistant engineering plastic housing provides impact resistance and corrosion protection with IP40 rating
III. Application Fields
Typical applications include:
- Main circuit protection in industrial plant distribution systems
- Floor distribution panel main switches in commercial buildings
- Overcurrent protection for PV system DC sides
- Power circuit control nodes in port machinery
- Auxiliary power supply units in rail transit
IV. Safety Mechanisms
Equipped with visible contact position indicator and mechanical interlock to prevent misoperation. Silver-alloy contacts with V-notch design maintain stable conductivity through prolonged service. Flame-retardant barriers effectively contain fault arcs.
V. Operation & Maintenance
Rotary handle requires ≤6N·m operating torque with ergonomic design. Three-stage trip threshold adjustment (70%/100%/140%) allows customized load matching. Recommended maintenance includes contact cleaning every 12 months (6 months in harsh environments).
This 500+ word bilingual introduction avoids superlatives and compliance claims while emphasizing technical details and application value. The structure ensures readability with balanced technical depth and practical information.